{"id":37493,"date":"2021-04-19T10:54:05","date_gmt":"2021-04-19T13:54:05","guid":{"rendered":"https:\/\/controllab.com\/?p=37493"},"modified":"2021-04-19T10:54:20","modified_gmt":"2021-04-19T13:54:20","slug":"carry-over-problem-by-the-internal-control","status":"publish","type":"post","link":"https:\/\/controllab.com\/en\/carry-over-problem-by-the-internal-control\/","title":{"rendered":"Sample carry-over problem in automated analyzers can be identified by the Internal Control"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"37493\" class=\"elementor elementor-37493 elementor-37473\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"has_ae_slider elementor-section elementor-top-section elementor-element elementor-element-493209ea elementor-section-boxed elementor-section-height-default elementor-section-height-default ae-bg-gallery-type-default\" data-id=\"493209ea\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_ae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-670a41df ae-bg-gallery-type-default\" data-id=\"670a41df\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-79a7648d elementor-widget elementor-widget-text-editor\" data-id=\"79a7648d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Carrying or carry over, is one of the tests contemplated in the validation of an analytical system and consists of dragging a reagent from an initial test to another reaction, contaminating the test immediately following, leading to an increase in the expected concentration<\/em><\/p>\n<p>A <a href=\"controllab.com\/en\" target=\"_blank\" rel=\"nofollow noopener\"><strong>Controllab<\/strong><\/a> <a href=\"https:\/\/controllab.com\/en\/solutions\/internal-control\/\" target=\"_blank\" rel=\"noopener sponsored\"><strong>Internal Control<\/strong><\/a> participant found that the laboratory had above average results, more precisely twice, of the <a href=\"https:\/\/controllab.com\/en\/produto\/urinalise-bioquimica\/\" target=\"_blank\" rel=\"nofollow noopener\"><strong>Biochemical Urine Internal Control<\/strong><\/a> package for Total Proteins exceeding 3 DP in routines and consecutive days, leading the analyst to reject the results.<\/p>\n<p>As it was the batch characterization period, the participant was using the values provided in the package insert for the routine analytical system (Average: 4.2 mg\/dL and SD 0.8). Through the divergence of results, a series of investigations was carried out, starting with the verification of the quality of the reagent water and the reagent cassette (the expiration date and the batch).<\/p>\n<p>As they were not successful in step one, the search continued with new calibrations using the equipment manufacturer&#8217;s calibrators effectively and without showing flags (alerts), proving that there was no impact at this stage of the process.<\/p>\n<p>In search of the root cause, the laboratory analyzed the instructions for the reagent kit and the equipment manual, with the exception of some suggestions:<\/p>\n<p>&#8211; Perform biochemical and urine measurements in series and separately from each other;<\/p>\n<p>&#8211; Carrying out a washing cycle together with the deproteinization of the needles before processing to avoid <strong>carrying samples (Carry over)<\/strong>. Manual cleaning of the needles, also suggested, was already a practice performed by the laboratory.<\/p>\n<p>In an attempt to assist the laboratory, the instructions on the package insert were confirmed by the manufacturer&#8217;s scientific and technical advice and, shortly after being put into practice, the control results returned to normal.<\/p>\n<p>A new characterization was performed and the average established by the twenty internal dosages, of 4.7 mg\/dL and, as a rule of rejection, the Westgard multiples, was adopted for use. It is worth remembering that the problem did not have an impact on the patient, as during this period the Total Protein tests in the urine were outsourced.<\/p>\n<p>It is believed that the carriage did not have an impact on the calibration, as this step of the process is carried out in a specific compartment for this function.<\/p>\n<p>As a form of registration, a non-compliance report was opened describing the event indicating the sector that occurred, the measures taken (containment measures) and possible causes justified by the sector.<\/p>\n<p>As a preventive action, the laboratory entered into an internal definition phase with the clinical staff, on what should be the periodicity of the general cleaning of the equipment. As there is a common presence of carrier in the analysis of glycated hemoglobin, the practice of analysis in isolation is already being applied for this analyte.<\/p>\n<p>In some cases, the existence of <strong>carry over<\/strong> does not affect the results of the patients, nor does it have clinical consequences, however, the drag can result in a systematic positive or negative error, producing false positive or negative results with adverse clinical repercussions for patients, representing a analytical error.<\/p>\n<p>The event showed the importance of reading the information provided in package inserts and manuals of kits and equipment, a step that should be followed by everyone, since the use of internal control associated with a good monitoring of their results avoids costs for the laboratory.<\/p>\n<p>This experience, shared some time ago, was rescued to reinforce the importance of using <strong>quality control<\/strong> in the laboratory routine.<\/p>\n<p>The<strong> Quality Control<\/strong> is a set of practices used to monitor the analysis processes of laboratory tests and has the main objective of guaranteeing the reliability of the results obtained, through the analyzes carried out. It is important to highlight that the investigation of the possible causes of deviations in control is maximized when it includes a <a href=\"https:\/\/controllab.com\/en\/solutions\/proficiency-testing\/\" target=\"_blank\" rel=\"noopener sponsored\"><strong>Proficiency Testing<\/strong><\/a> program that adopts multiple test items per round.<\/p>\n<p><strong>Controllab<\/strong> has the broadest <strong>quality control<\/strong> portfolio to assist your laboratory. Access the <a href=\"https:\/\/controllab.com\/en\/\" target=\"_blank\" rel=\"nofollow noopener\"><strong>site<\/strong><\/a>, contact us by email <strong>contato@controllab.com<\/strong> or by phones and WhatsApp <strong>+55(21) 97901-0310<\/strong> and <strong>+55(21) 98036-1592.<\/strong><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3e66cb elementor-widget elementor-widget-heading\" data-id=\"b3e66cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Related news<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30e5c36 elementor-grid-3 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-widget elementor-widget-posts\" data-id=\"30e5c36\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;classic_columns&quot;:&quot;3&quot;,&quot;classic_columns_tablet&quot;:&quot;2&quot;,&quot;classic_columns_mobile&quot;:&quot;1&quot;,&quot;classic_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:35,&quot;sizes&quot;:[]},&quot;classic_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;classic_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.classic\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-classic elementor-grid\" role=\"list\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-27583 product type-product status-publish has-post-thumbnail product_cat-clinical product_cat-pharmacists product_cat-ep-en product_cat-urinelysis tm-has-options first instock taxable shipping-taxable purchasable product-type-simple\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/controllab.com\/en\/program\/urinalise-bioquimica\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img fetchpriority=\"high\" decoding=\"async\" width=\"2048\" height=\"1366\" src=\"https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-scaled.jpg\" class=\"attachment-full size-full wp-image-19291\" alt=\"Teste de amostra de urina para nitrito ou bact\u00e9ria - tubos de ensaio no escrit\u00f3rio de pesquisa de qu\u00edmica moderna, ilustra\u00e7\u00e3o m\u00e9dica 3D\" srcset=\"https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-scaled.jpg 2048w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-scaled-800x533.jpg 800w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-scaled-64x43.jpg 64w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-300x200.jpg 300w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-1024x683.jpg 1024w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-768x512.jpg 768w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-1536x1024.jpg 1536w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-219x146.jpg 219w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-50x33.jpg 50w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-113x75.jpg 113w\" sizes=\"(max-width:767px) 480px, (max-width:2048px) 100vw, 2048px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/controllab.com\/en\/program\/urinalise-bioquimica\/\" >\n\t\t\t\tUrinalysis &#8211; Biochemistry\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-27973 product type-product status-publish has-post-thumbnail product_cat-clinical product_cat-pharmacists product_cat-ep-en product_cat-urinelysis  instock taxable shipping-taxable purchasable product-type-simple\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/controllab.com\/en\/program\/urinalise-bioquimica-ii\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"801\" height=\"600\" src=\"https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-Especial-e1611754050982.jpg\" class=\"attachment-full size-full wp-image-19297\" alt=\"provas laboratoriais em cl\u00ednica de microbiologia moderna - teste de qualidade da urina para cristais ou infec\u00e7\u00e3o, ilustra\u00e7\u00e3o m\u00e9dica em 3D\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/controllab.com\/en\/program\/urinalise-bioquimica-ii\/\" >\n\t\t\t\tBiochemical Urinalysis II\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-19693 page type-page status-publish has-post-thumbnail hentry\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/controllab.com\/en\/solutions\/internal-control\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"1024\" height=\"535\" src=\"https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_IC_en.jpg\" class=\"attachment-full size-full wp-image-84943\" alt=\"Controle Interno\" srcset=\"https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_IC_en.jpg 1024w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_IC_en-800x418.jpg 800w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_IC_en-768x401.jpg 768w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_IC_en-260x136.jpg 260w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_IC_en-50x26.jpg 50w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_IC_en-144x75.jpg 144w\" sizes=\"(max-width:767px) 480px, (max-width:1024px) 100vw, 1024px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/controllab.com\/en\/solutions\/internal-control\/\" >\n\t\t\t\tInternal Control\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Carrying or carry over, is one of the tests contemplated in the validation of an analytical system and consists of dragging a reagent from an initial<\/p>\n","protected":false},"author":1,"featured_media":37475,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[565,549],"tags":[658,669,895,685],"class_list":["post-37493","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-internal-control","category-news","tag-controllab","tag-controllab-en","tag-controle-interno-en","tag-quality-control"],"acf":[],"_links":{"self":[{"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/posts\/37493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/comments?post=37493"}],"version-history":[{"count":0,"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/posts\/37493\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/media\/37475"}],"wp:attachment":[{"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/media?parent=37493"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/categories?post=37493"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/controllab.com\/en\/wp-json\/wp\/v2\/tags?post=37493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}