{"id":37491,"date":"2021-04-19T10:54:05","date_gmt":"2021-04-19T13:54:05","guid":{"rendered":"https:\/\/controllab.com\/?p=37491"},"modified":"2021-04-19T10:56:56","modified_gmt":"2021-04-19T13:56:56","slug":"arrastre-identifica-mediante-el-control-interno","status":"publish","type":"post","link":"https:\/\/controllab.com\/es\/arrastre-identifica-mediante-el-control-interno\/","title":{"rendered":"El problema del arrastre de muestras en analizadores autom\u00e1ticos puede identificarse mediante el Control Interno"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"37491\" class=\"elementor elementor-37491 elementor-37473\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"has_ae_slider elementor-section elementor-top-section elementor-element elementor-element-493209ea elementor-section-boxed elementor-section-height-default elementor-section-height-default ae-bg-gallery-type-default\" data-id=\"493209ea\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_ae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-670a41df ae-bg-gallery-type-default\" data-id=\"670a41df\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-79a7648d elementor-widget elementor-widget-text-editor\" data-id=\"79a7648d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>El arrastre o carry-over, es una de las pruebas contempladas en la validaci\u00f3n de un sistema anal\u00edtico y consiste en transportar un reactivo de un ensayo inicial a otra reacci\u00f3n, contaminando la prueba inmediatamente posterior, provocando un aumento de la concentraci\u00f3n esperada.<\/em><\/p>\n<p>Un participante del <a href=\"https:\/\/controllab.com\/es\/soluciones\/control-interno\/\" target=\"_blank\" rel=\"nofollow noopener\"><strong>Control Interno<\/strong><\/a> de <strong><a href=\"controllab.com\/es\/\" target=\"_blank\" rel=\"noopener sponsored\">Controllab<\/a><\/strong> descubri\u00f3 que el laboratorio ten\u00eda resultados por encima del promedio, precisamente el doble, del prospecto de <strong><a href=\"https:\/\/controllab.com\/es\/produto\/urinalise-bioquimica\/\" target=\"_blank\" rel=\"nofollow noopener\">Control Interno de Orina Bioqu\u00edmica<\/a><\/strong> para Prote\u00ednas Totales que exced\u00edan 3 DP en rutinas y d\u00edas consecutivos, lo que llev\u00f3 al analista a rechazar los resultados.<\/p>\n<p>Como era el per\u00edodo de caracterizaci\u00f3n del lote, el participante estaba utilizando los valores proporcionados en el prospecto para el sistema anal\u00edtico de rutina (promedio: 4,2 mg\/dL y DE 0,8). A trav\u00e9s de la divergencia de resultados, se llev\u00f3 a cabo una serie de investigaciones, comenzando por la verificaci\u00f3n de la calidad del agua del reactivo y el casete del reactivo (la fecha de caducidad y el lote).<\/p>\n<p>Como no tuvieron \u00e9xito en el paso uno, la b\u00fasqueda continu\u00f3 con nuevas calibraciones utilizando los calibradores del fabricante del equipo de manera efectiva y sin mostrar <em>flags<\/em> (alertas), lo que demuestra que no hubo impacto en esta etapa del proceso.<\/p>\n<p>En busca de la causa ra\u00edz, el laboratorio analiz\u00f3 las instrucciones del kit de reactivos y el manual del equipo, con la excepci\u00f3n de algunas sugerencias:<\/p>\n<p>&#8211; Realizar las dosis de bioqu\u00edmica y de orina en serie y por separado entre s\u00ed;<\/p>\n<p>&#8211; Realizar un ciclo de lavado junto con la desproteinizaci\u00f3n de las agujas antes del procesamiento para evitar el <strong>arrastre de muestras (carry over)<\/strong>. La limpieza manual de las agujas, tambi\u00e9n sugerida, ya era una pr\u00e1ctica realizada por el laboratorio.<\/p>\n<p>En un intento de ayudar al laboratorio, las instrucciones del prospecto fueron confirmadas por el asesoramiento cient\u00edfico y t\u00e9cnico del fabricante y, poco despu\u00e9s de su puesta en pr\u00e1ctica, los resultados del control volvieron a la normalidad.<\/p>\n<p>Se realiz\u00f3 una nueva caracterizaci\u00f3n y se adopt\u00f3 para su uso la media establecida por las veinte dosis internas, de 4,7 mg\/dL y, como regla de rechazo, el m\u00faltiplo de Westgard. Cabe recordar que el problema no afect\u00f3 al paciente, ya que durante este per\u00edodo se subcontrataron las pruebas de Prote\u00ednas Totales en la orina.<\/p>\n<p>Se cree que el arrastre no tuvo impacto en la calibraci\u00f3n, ya que este paso del proceso se realiza en un compartimento espec\u00edfico para esta funci\u00f3n.<\/p>\n<p>Como forma de registro, se abri\u00f3 un informe de incumplimiento describiendo el evento indicando el sector que ocurri\u00f3, las medidas tomadas (medidas de contenci\u00f3n) y las posibles causas justificadas por el sector.<\/p>\n<p>Como acci\u00f3n preventiva, el laboratorio entr\u00f3 en una fase de definici\u00f3n interna con el personal cl\u00ednico, sobre cu\u00e1l debe ser la periodicidad de la limpieza general del equipo. Como existe una presencia com\u00fan de portador en el an\u00e1lisis de la hemoglobina glucosilada, ya se est\u00e1 aplicando la pr\u00e1ctica del an\u00e1lisis aislado para este analito.<\/p>\n<p>En algunos casos, la existencia de <strong>arrastre<\/strong> no afecta los resultados de los pacientes, ni trae consecuencias cl\u00ednicas, sin embargo, el arrastre puede resultar en un error sistem\u00e1tico positivo o negativo, produciendo resultados falsos positivos o negativos con repercusi\u00f3n cl\u00ednica adversa para los pacientes, lo que representa un fen\u00f3meno de error anal\u00edtico.<\/p>\n<p>Lo sucedido mostr\u00f3 la importancia de leer la informaci\u00f3n que se brinda en los prospectos y manuales de kits y equipos, paso que deben seguir todos, ya que el uso del control interno asociado a un buen seguimiento de sus resultados evita costos para el laboratorio.<\/p>\n<p>Esta experiencia, compartida hace alg\u00fan tiempo, fue rescatada para reforzar la importancia de utilizar el <strong>control de calidad<\/strong> en la rutina del laboratorio.<\/p>\n<p>El <strong>Control de Calidad<\/strong> es un conjunto de pr\u00e1cticas utilizadas para monitorear los procesos de an\u00e1lisis de las pruebas de laboratorio y tiene como objetivo principal garantizar la confiabilidad de los resultados obtenidos, a trav\u00e9s de los an\u00e1lisis realizados. Es importante resaltar que la investigaci\u00f3n de las posibles causas de las desviaciones en el control se maximiza cuando se incluye un programa de <strong><a href=\"https:\/\/controllab.com\/es\/soluciones\/ensayo-de-aptitud\/\" target=\"_blank\" rel=\"noopener sponsored\">Ensayo de Aptitud<\/a><\/strong> que adopta m\u00faltiples \u00edtems de ensayo por ronda.<\/p>\n<p><strong>Controllab<\/strong> tiene el portafolio m\u00e1s amplio de <strong>control de calidad<\/strong> para ayudar a su laboratorio. Acceda al <strong><a href=\"https:\/\/controllab.com\/es\/\" target=\"_blank\" rel=\"nofollow noopener\">sitio web<\/a><\/strong>, cont\u00e1ctenos por correo electr\u00f3nico <strong>contato@controllab.com<\/strong> o por tel\u00e9fonos y WhatsApp <strong>+55 (21) 97901-0310<\/strong> y <strong>+55(21) 98036-1592.<\/strong><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3e66cb elementor-widget elementor-widget-heading\" data-id=\"b3e66cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Noticias relacionadas <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30e5c36 elementor-grid-3 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-widget elementor-widget-posts\" data-id=\"30e5c36\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;classic_columns&quot;:&quot;3&quot;,&quot;classic_columns_tablet&quot;:&quot;2&quot;,&quot;classic_columns_mobile&quot;:&quot;1&quot;,&quot;classic_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:35,&quot;sizes&quot;:[]},&quot;classic_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;classic_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.classic\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-classic elementor-grid\" role=\"list\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-27584 product type-product status-publish has-post-thumbnail product_cat-clinico-es product_cat-ep-es product_cat-farmaceuticos-es-2 product_cat-urinalisis tm-has-options first instock taxable shipping-taxable purchasable product-type-simple\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/controllab.com\/es\/programa\/urinalise-bioquimica\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img fetchpriority=\"high\" decoding=\"async\" width=\"2048\" height=\"1366\" src=\"https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-scaled.jpg\" class=\"attachment-full size-full wp-image-19292\" alt=\"Teste de amostra de urina para nitrito ou bact\u00e9ria - tubos de ensaio no escrit\u00f3rio de pesquisa de qu\u00edmica moderna, ilustra\u00e7\u00e3o m\u00e9dica 3D\" srcset=\"https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-scaled.jpg 2048w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-scaled-800x533.jpg 800w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-scaled-64x43.jpg 64w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-300x200.jpg 300w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-1024x683.jpg 1024w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-768x512.jpg 768w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-1536x1024.jpg 1536w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-219x146.jpg 219w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-50x33.jpg 50w, https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-113x75.jpg 113w\" sizes=\"(max-width:767px) 480px, (max-width:2048px) 100vw, 2048px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/controllab.com\/es\/programa\/urinalise-bioquimica\/\" >\n\t\t\t\tAn\u00e1lisis de Orina &#8211; Bioqu\u00edmica\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-27972 product type-product status-publish has-post-thumbnail product_cat-clinico-es product_cat-ep-es product_cat-farmaceuticos-es-2 product_cat-urinalisis  instock taxable shipping-taxable purchasable product-type-simple\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/controllab.com\/es\/programa\/urinalise-bioquimica-ii\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"801\" height=\"600\" src=\"https:\/\/controllab.com\/wp-content\/uploads\/Urin\u00e1lise-Bioqu\u00edmica-Especial-e1611754050982.jpg\" class=\"attachment-full size-full wp-image-19298\" alt=\"provas laboratoriais em cl\u00ednica de microbiologia moderna - teste de qualidade da urina para cristais ou infec\u00e7\u00e3o, ilustra\u00e7\u00e3o m\u00e9dica em 3D\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/controllab.com\/es\/programa\/urinalise-bioquimica-ii\/\" >\n\t\t\t\tAn\u00e1lisis Bioqu\u00edmico de Orina II\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-19694 page type-page status-publish has-post-thumbnail hentry\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/controllab.com\/es\/soluciones\/control-interno\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"1024\" height=\"535\" src=\"https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_CI_es.jpg\" class=\"attachment-full size-full wp-image-84944\" alt=\"Controle Interno\" srcset=\"https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_CI_es.jpg 1024w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_CI_es-800x418.jpg 800w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_CI_es-768x401.jpg 768w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_CI_es-260x136.jpg 260w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_CI_es-50x26.jpg 50w, https:\/\/controllab.com\/wp-content\/uploads\/imagem_destaque_CI_es-144x75.jpg 144w\" sizes=\"(max-width:767px) 480px, (max-width:1024px) 100vw, 1024px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/controllab.com\/es\/soluciones\/control-interno\/\" >\n\t\t\t\tControl Interno\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>El arrastre o carry-over, es una de las pruebas contempladas en la validaci\u00f3n de un sistema anal\u00edtico y consiste en transportar un reactivo de un ensayo<\/p>\n","protected":false},"author":1,"featured_media":37476,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[566,545],"tags":[886,690,885,896,665,673],"class_list":["post-37491","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-control-interno","category-noticias-es","tag-arrastre","tag-control-de-calidad","tag-control-interno","tag-controle-interno-es","tag-controllab-es","tag-controllab-es-2"],"acf":[],"_links":{"self":[{"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/posts\/37491","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/comments?post=37491"}],"version-history":[{"count":0,"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/posts\/37491\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/media\/37476"}],"wp:attachment":[{"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/media?parent=37491"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/categories?post=37491"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/controllab.com\/es\/wp-json\/wp\/v2\/tags?post=37491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}